3 Water Module
3.6 Damming and Diverting
3.6.7 Spillway Requirements
Weir Width Requirements (m)
| |
|
Catchment Size km2 |
|
|
0.2 |
0.4 |
0.6 |
0.8 |
1 |
| Depth (m) |
0.3 |
- |
- |
- |
- |
- |
| 0.5 |
7 |
- |
- |
- |
- |
| 1.0 |
3 |
4 |
4 |
6 |
6 |
| 1.5 |
2 |
2 |
3 |
3 |
4 |
| 5.0 |
- |
2 |
2 |
2 |
3 |

3.6.7.1 Calculation Assumptions
There have been several assumptions made to generate the above guidelines for spillway requirements.
- The Rational Method was used to estimate flows.
- The rainfall event was assumed to be a 50 year event multiplied by 1.6 which was then used to derive the maximum required spillway flow.
- An average for the Region was used.
- The dam is assumed to be full when the rainfall event occurs.
- Rainfall time of concentration has been assumed to be dependent on the catchment size by the following table:
Time of concentration relative to catchment size
| Catchment Size km2 |
0.2 |
0.4 |
0.6 |
0.8 |
1.0 |
| Assumed Time of Concentration (m) |
10 |
20 |
30 |
30 |
30 |
- The run-off coefficients were also assumed to be dependent on the catchment size:
Run-off coefficient relative to catchment size
| Catchment Size (km2) |
0.2 |
0.4 |
0.6 |
0.8 |
1.0 |
| Run-off Coefficient |
0.8 |
0.8 |
0.7 |
0.7 |
0.6 |
- The weir flow calculations were derived using the following formula:
q=2/3*H*(2/3*g*H)1/2
where:
q = flow (m3)/meter width (m)
H = depth of water about the weir crest (m)
G = gravity (9.81m2/s)